Range |
300 to 1,400 Channels/cell
|
Organism |
Bacteria Escherichia coli |
Reference |
Bialecka-Fornal M, Lee HJ, DeBerg HA, Gandhi CS, Phillips R. Single-cell census of mechanosensitive channels in living bacteria. PLoS One. 2012 7(3):e33077. p.4 right column 2nd paragraphPubMed ID22427953
|
Method |
Fluorescence microscopy |
Comments |
MscL=MechanoSensitive (MS) channels of Large conductance. The
fluorescence microscopy measurements indicated that the mean
number of channels per cell determined by total integrated
fluorescence is on the order of 300–1400 (10^2 to 10^3 channels per
µm^2), depending on culturing conditions. |
Entered by |
Uri M |
ID |
107632 |