Range |
Table - link Channels/cell
|
Organism |
Bacteria Escherichia coli |
Reference |
Bialecka-Fornal M, Lee HJ, DeBerg HA, Gandhi CS, Phillips R. Single-cell census of mechanosensitive channels in living bacteria. PLoS One. 2012 7(3):e33077. p.7 table 2PubMed ID22427953
|
Method |
Researchers measure the mean number
of MscL channels per cell under various culturing conditions using
quantitative Western blots and single-molecule calibrated fluorescence
microscopy. |
Comments |
MscL=MechanoSensitive (MS) channels of Large conductance. The
agreement between the mean values found from fluorescence
microscopy and quantitative Western blots is summarized in
Table 2. See notes beneath table. |
Entered by |
Uri M |
ID |