Conductivity of mechanosensitive channels
| Range | ~3 MscL: ~1 MscS: ~0.4 MscM nanoSiemen |
|---|---|
| Organism | Unspecified |
| Reference | Haswell ES, Phillips R, Rees DC. Mechanosensitive channels: what can they do and how do they do it? Structure. 2011 Oct 12 19(10):1356-69. p.1358 right column bottom paragraphPubMed ID22000509 |
| Comments | MscS=Mechanosensitive channel of Small conductance. MscL=Mechanosensitive channel of Large conductance. MscM=the mini-conductance channel |
| Entered by | Uri M |
| ID | 107627 |