| Value |
1880
µm^2/sec
Range: Table - link µm^2/sec
|
| Organism |
Generic |
| Reference |
Maxarei, A.F. and Sandall, D.C., 1980, Diffusion coefficients for helium, hydrogen and carbon dioxide in water at 25 C. AIChE J. 26, 154-157. p.155 table 1 |
| Method |
"A wetted wall column technique was used with a relatively long (0.200 m) stainless
steel tube as the wetted wall. Water was mixed with a small amount of a surface active agent to suppress surface
ripples and give well-defined hydrodynamics." |
| Comments |
"The average values along with their percent mean deviations and percent standard deviations are listed in Table 1. The maximum experimental error is estimated to be about 10.8%, which may be compared with the deviations tabulated in Table 1." |
| Entered by |
Uri M |
| ID |
102625 |