delta pH across the inner membrane of a respiring mitchondria
Value | 1 pH units |
---|---|
Organism | Mitochondria |
Reference | Molecular Cell Biology, Lodish et al, 4th ed. Section 16.2 |
Method | By trapping fluorescent pH-sensitive dyes inside vesicles formed from the inner mitochondrial membrane, researchers can measure the inside pH during oxidative phosphorylation. |
Comments | equivalent to about 60 meV |
Entered by | Ron Milo - Admin |
ID | 101104 |